Network protocols
7.2 IPv6 protocol
Syntax
Call up the command with the following parameters:
ipv6 route <prefix> <prefix len>
(
[<NextHop>]
{
vlan <id>[<administrative distance>] [unicast]|[<administrative distance>] [unicast]
| [<interface-type> <interface-id>][<administrative distance>] [unicast]
}
)
The parameters have the following meaning:
Parameter
Description
prefix
IPv6 address
prefix len
Number of bits belonging to the prefix
(from left to right)
NextHop
IPv6 address to which the selected addresses will be forwarded
vlan
Keyword for a VLAN connection
id
Number of the addressed VLAN
administrative
Value for the administrative distance
distance
unicast
Addressing mode unicast
interface-type
Type or speed of the interface
interface-id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The entry is configured.
Further notes
You delete a static entry from the IPv6 routing table with the
You display the IPv6 routing table with the
7.2.3.8

no ipv6 route

Description
With this command, you delete a static entry from the IPv6 routing table.
316
Range of values / note
Enter a valid IPv6 address.
1 ... 128 bits
128: The node (host) itself
Enter a valid IPv6 address.
-
1 ... 4094
0 ... 65535
Default: 1
-
Enter a valid interface.
no ipv6 route
command.
show ipv6 route
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.