No Login Authentication - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

The parameters have the following meaning:
Parameter
radius
local-and-radius
radius-fallback-
local
Result
The authentication is made according to the selected parameter.
Further notes
You disable the authentication via a RADIUS server with the
command.
You can display the status of this function and other information with the
information
11.2.2.2

no login authentication

Description
With this command, you disable authentication via a RADIUS server.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no login authentication
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
The login is via a RADIUS server.
The login is possible both with the
users that exist in the firmware (user
name and password) and via a
RADIUS server.
The authentication must be handled
via a RADIUS server.
command.
Security and authentication
11.2 RADIUS client
Range of values / note
-
The local users have priority.
The user is first searched for in the
local database. If the user does
not exist there, a RADIUS query is
sent.
A local authentication is performed
only when the RADIUS server
cannot be reached in the network.
no login authentication
show device
819