Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no poe pse <integer(1-4)> MaximumPower
The parameters have the following meaning:
Parameter
integer
Result
The value for the maximum power is deleted.
Further notes
You configure the value for the parameter "Maximum Power" with the
command.
3.5.2.3

poe pse usage

Description
With this command, you set a value (as a percentage) for the "Usage Threshold" parameter.
This specifies how many percent of the maximum power the connected devices will use. As
soon as the power being used by the end devices exceeds this percentage, an event is
triggered. An event is also entered in the log. You display the entries of the log with the
command
"show logbook (Page 888)".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Number of the PSE
. You will find more information on this command in the section
show logbook
Configuration
3.5 PoE
Range of values / note
1 ... 4
poe pse MaximumPower
131