Requirement
● The interface is an IPv6 interface.
● You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call the command without parameter assignment:
no ipv6 ospf hello-interval
Result
The interval is reset.
Further notes
You enable OSPFv3 routing with the
You configure the interval with the
You display the configuration with the
9.3.4.7

ipv6 ospf metric

Description
With this command, you specify the metric for OSPFv3.
Note
This command is available only with layer 3.
Requirement
● The interface is an IPv6 interface.
● You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 ospf metric <metric>
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.
ipv6 router ospf
ipv6 ospf hello-interval
show ipv6 ospf interface
Layer 3 functions
9.3 OSPFv3 (IPv6)
command.
command.