Diagnostics
12.1 Event and fault handling
● Message if there is an incorrect login
● Message when there is aRemote Monitoring alarm (RMON alarm)
● Message when there is a status change in the power supply
● Message when there is a status change in the redundancy manager (RM)
● Message when there is a status change on a standby connection
● Message when there is a status change in the error monitoring
● Message when there is a change in the spanning tree
● Message when there is a status change of the VRRP routers
● Message if there is a status change in the detection of network loops
● Message on status change of OSPF routers
● Message when there is a status change in the diagnostics data
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the Syslog server
● Sending an e-mail
● Sending an SNMP trap
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
event config
{cold-warmstart|linkchange|authentication-failure|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-change|dot1x-port-auth-
state-change|poe- state-change|fmp-state-change|env-data-change|all}
{logtable|syslog|email|trap|faults|all}
The parameters have the following meaning:
Parameter
cold-warmstart
linkchange
authentication-
failure
rmon-alarm
power-change
rm-state-change
standby-state-
change
896
rmon-alarm|power-change|rm-state-change|standby-state-change|faultstate-change|
Description
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a RMONalarm
Message when there is a status change in the power supply
Message when there is a status change in the redundancy manager
Message when there is a status change on a standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11