Parameter
port-channel
port-channel-id
rx
tx
both
vlan
vlan-id
mac-acl
ip-acl
acl-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameters from the parameter list, the default value (both) is used.
Note
VLAN and ACL mirroring
Tx mirroring is not supported with VLAN or ACL mirroring.
Result
As soon as you have configured the settings for the port to be monitored and the destination
port, the session is complete and active.
Further notes
You delete the source for mirroring a port with the
You end and delete a session with the
You display the configuration settings with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Keyword for a port channel connection
Number of the addressed port channel
Received data traffic will be mirrored
(received)
Transmitted data traffic will be mirrored
(transmitted)
Received and sent data traffic will be
mirrored
Keyword for a VLAN connection
Number of the VLAN
Keyword for a MAC access control list
Keyword for an IP access control list
Number of the Access Control List
no monitor session
show monitor session
Range of values / note
-
1 ... 8
-
-
-
It can happen that data packets
are visible on the monitor port that
were not received in the defined
VLAN. These data packets come
from functions that are enabled on
the device, e.g. SIMATIC time
client. To avoid these data pack-
ets when VLAN mirroring, disable
the relevant functions on the de-
vice before a recording.
1 ... 4094
-
-
-
no monitor session ... source
command.
command.