Siemens SCALANCE X-400 Compact Operating Instructions

Simatic net, industrial ethernet switches, extender modules
Hide thumbs Also See for SCALANCE X-400:

Advertisement

SCALANCE X-

SIMATIC NET
Industrial Ethernet switches
SCALANCE X-400 extender
modules
Compact Operating Instructions
04/2013
A5E00367421-10
400 extender modules
___________________

Introduction
___________________
Safety instructions
___________________
Description
___________________
Assembly
___________________
Certification
___________________
Technical specifications
___________________
Graphics
1
2
3
4
5
6
7

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X-400

  • Page 1 ___________________ SCALANCE X- 400 extender modules Introduction ___________________ Safety instructions ___________________ Description SIMATIC NET ___________________ Assembly Industrial Ethernet switches ___________________ SCALANCE X-400 extender Certification modules ___________________ Technical specifications Compact Operating Instructions ___________________ Graphics 04/2013 A5E00367421-10...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Extender module EM495-8 - technical specifications ..............35 Extender module EM496-4 - technical specifications ..............36 Graphics ..............................37 Dimension drawing - EM495-8 extender module.................37 Dimension drawing - EM496-4 extender module.................39 Index................................ 41 SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 4 Table of contents SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 5: Introduction

    Content of the document These operating instructions (compact) contain information with which you will be able to install a device of the SCALANCE X-400 extender modules product line. Where can I find more detailed information on the product? A CD is supplied with the IE Switch X-400 basic devices on which you will find a detailed description of the products in PDF format in the relevant subfolder.
  • Page 6 Introduction SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 7: Safety Instructions

    There is an additional requirement if devices are operated with a redundant power supply: If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements. WARNING Opening the device DO NOT OPEN WHEN ENERGIZED. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 8 Requirements for the cabinet/enclosure When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 9 This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 10 Safety instructions 2.1 Important notes on using the device SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 11: Description

    The transmission rate of the Ethernet ports is 10 Mbps or as a Fast Ethernet port 100 Mbps. No media module is required for data transfer with this extender module. Figure 3-1 Basic device with twisted pair extender module SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 12 For slots 12 and 13 of the twisted pair extender EM495-8, you can use the cover that can be used on slots 9 through 11 on the basic device. Two CV490 4x100 covers are supplied with the twisted pair extender. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 13: Em496-4 Extender For Media Modules

    The required slot (for example no. 1) must remain occupied to allow the removal and insertion of the other media modules (for example slots 2-4) during ongoing operation. The media module plug connectors are protected by protective caps. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 14 3.2 EM496-4 extender for media modules Connector Depending on the media module, the connectors used are 2x2 BFOC sockets or SC duplex sockets. Figure 3-3 Basic device with media module extender SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 15 Description 3.2 EM496-4 extender for media modules Figure 3-4 Empty media module extender EM496-4 without protective caps for the media module terminal strips and without covers SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 16 Four CV490 2x100 covers are supplied with the twisted media module extender EM496-4. The media module plug connectors are also protected from damage by protective caps. Figure 3-5 Media module extender EM496-4 with media module MM491-2 on slot and with covers SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 17: Unpacking And Checking

    Unpacking and checking Unpacking, checking 1. Make sure that the package is complete. 2. Check all the parts for transport damage. WARNING Do not use any parts that show evidence of damage! SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 18 Description 3.3 Unpacking and checking SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 19: Assembly

    3. Remove the side panel of the basic device from the basic device to the right. Note Keep the panel in a safe place in case the extender needs to be removed again later. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 20 9. Fit the CV490 4x100 cover to slot 11 of the basic device and slots 12 and 13 of the twisted pair extender. Figure 4-1 Installing the twisted pair extender on the S7-300 standard rail SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 21 11. The screws lock the two guide bolts, so do not use excessive force when tightening them. 9. Fit a suitable cover on slot 11 of the basic device. Note The basic device must not be used permanently without the right side panel. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 22 Then push the extender module to the left as far as it will go so that it is flush with the right side of the basic device. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 23 9. Fit the CV490 4x100 cover to slot 11 of the basic device and slots 12 and 13 of the twisted pair extender. Figure 4-2 Installing the twisted pair extender on the 35 mm DIN rail SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 24 11. The screws lock the two guide bolts, so do not use excessive force when tightening them. 8. Fit a suitable cover on slot 11 of the basic device. Note The basic device must not be used permanently without the right side panel. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 25: Installing / Uninstalling The Em496-4 Media Module Extender For Scalance X414-3E

    7. Using a slotted screwdriver with a 5.5 mm wide blade, tighten the captive screw between slots 13 and 14 in the lower part of the extender module. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 26 CV490 2x100 covers are in place. Figure 4-3 Installing the media module extender on the S7-300 standard rail SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 27 11. The screws lock the two guide bolts, so do not use excessive force when tightening them. 8. Fit a suitable cover on slot 11 of the basic device. Note The basic device must not be used permanently without the right side panel. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 28 5. The spring clip must be located behind the edge of the DIN rail so that it is visible from the rear of the frame. 6. Press the extender module down and push in the lower part until you hear it click into place in the DIN rail. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 29 CV490 2x100 covers are in place. Figure 4-4 Installing the media module extender on the 35 mm DIN rail SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 30 11. The screws lock the two guide bolts, so do not use excessive force when tightening them. 8. Fit a suitable cover on slot 11 of the basic device. Note The basic device must not be used permanently without the right side panel. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 31: Certification

    The SIMATIC NET product meets the requirements of the EC Directive: 2004/108/EEC "Electromagnetic Compatibility" The product is designed for use in the following areas: Area of application Requirements Emission Immunity Industrial area EN 61000-6-4 : 2001 EN 61000-6-2: 2001 SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 32 This product is not a machine in the sense of the EC Machinery Directive. There is therefore no declaration of conformity relating to the EC Machinery Directive 89/392/EEC for this product. SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 33 Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 A and Non Incendive / Class I / Zone 2 / Group IIC / T4 Note for Australia The product meets the requirements of the AS/NZS 2064 standard (Class A). SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 34 Approved for use in: Cl. 1, Div. 2, GP. A, B, C, D, T4 A Cl. 1, Zone 2, GP. IIC T4 Cl. 1, Zone 2, Aex nC IIC T4 Report no. E240480 SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 35: Technical Specifications

    RF interference level EN 55081 Class A Immunity EN 61000-6-2: 2001 Construction Dimensions (W x H x D) 86 x 145 x 112.4 mm Weight 560 g Degree of protection IP20 SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 36: Extender Module Em496-4 - Technical Specifications

    RF interference level EN 55081 Class A Immunity EN 61000-6-2: 2001 Construction Dimensions (W x H x D) 154 x 145 x 112.4 mm Weight 980 g Degree of protection IP20 SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 37: Graphics

    Graphics Dimension drawing - EM495-8 extender module Dimension drawing EM495-8 Figure 7-1 Extender module EM495-8 front SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 38 Graphics 7.1 Dimension drawing - EM495-8 extender module Figure 7-2 Extender module EM495-8 left SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 39: Dimension Drawing - Em496-4 Extender Module

    Graphics 7.2 Dimension drawing - EM496-4 extender module Dimension drawing - EM496-4 extender module Dimension drawing EM496-4 Figure 7-3 Extender module EM496-4 front SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 40 Graphics 7.2 Dimension drawing - EM496-4 extender module Figure 7-4 Extender module EM496-4 left SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 41: Index

    Media module extender, 13 Twisted pair extender, 11 Hazardous area, 8 Installation Media module extender, 25 Twisted pair extender, 19 Safety notices, 7 UL-HazLoc, 9 Uninstalling Media module extender, 30 Twisted pair extender, 24 SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...
  • Page 42 Index SCALANCE X-400 extender modules Compact Operating Instructions, 04/2013, A5E00367421-10...

Table of Contents