Syntax
Call up the command with the following parameters:
link {up|down}[{<interface-type><interface-id>}]
The parameters have the following meaning:
Parameter
up
down
interface-type
interface-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select an interface, the function is enabled for all available interfaces.
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You display the setting with the
You disable the function with the
12.1.6.11

no link

Description
With this command, you disable the monitoring of the physical network connections for cable
breaks or for pulling of the connector.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no {up|down}[{<interface-type><interface-id>}]
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Only the establishment of a connection
is signaled
Only a break on a connection is sig-
naled
Type or speed of the interface
Module no. and port no. of the interface
show events faults config
command.
no link
Diagnostics
12.1 Event and fault handling
Range of values / note
-
-
Enter a valid interface.
command.