No Ip Igmp Snooping Querier - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call the command without parameters:
ip igmp snooping querier
As default the function is "disabled".
Result
The IGMP snooping switch is configured as querier.
Further notes
You delete the setting with the
You can display the status of this function and other information with the
snooping
8.4.1.2

no ip igmp snooping querier

Description
With this command, you delete the configuration of an IGMP snooping switch as querier.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ip igmp snooping querier
Result
The configuration of the IGMP snooping switch as querier is deleted.
Further notes
You configure the setting with the
You can display the status of this function and other information with the
snooping
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
no ip igmp snooping querier
command.
command.
ip igmp snooping querier
Layer 2 management protocols
8.4 IGMP querier
command.
show ip igmp
command.
show ip igmp
469