info
6.1.2.6

no protocol-vlan

Description
With this command, you disable the protocol-based classification on all interfaces.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no protocol-vlan
Result
The classification is disabled.
Further notes
You enable the setting with the
You can display the status of this function and other information with the
info
6.1.2.7

subnet-vlan

Description
With this command, you enable IPv4 subnet-based VLAN on all interfaces.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.
command.
command.
no protocol-vlan
command.
protocol-vlan
Network structures
6.1 VLAN
show vlan device