8.5.5.2

ring-redundancy hrpobserver

Description
With this command, you enable the observer or restart it.
The "observer" function is only available in HRP rings. The observer monitors malfunctions
of the redundancy manager or incorrect configurations of an HRP ring.
If the observer is enabled, it can interrupt the connected ring if errors are detected. To do
this, the observer switches a ring port to the "blocking" status. When the error is resolved,
the observer enables the port again.
If numerous errors occur in quick succession, the observer no longer enables its port
automatically. The ring port remains permanently in the "blocking" status. This is signaled by
the error LED and a message text. After the errors have been eliminated, you can enable the
port again with this command and the parameter
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ring-redundancy hrpobserver [restart]
The parameters have the following meaning:
Parameter
restart
If you do not specify the optional parameter, the observer is enabled.
Result
The observer is enabled or restarted.
Further notes
You disable the observer with the
You can display the status of this function and other information with the
redundancy
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Restarts the observer.
no ring-redundancy hrpobserver
command.
Layer 2 management protocols
8.5 Ring redundancy and standby connection
.
restart
command.
show ring-