No Cli-Console-Timeout - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Configuration
3.1 System
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
cli-console-timeout [seconds(60-600)]
The parameters have the following meaning:
Parameter
seconds
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logout with the
You display the current timeout setting with the
3.1.12.2

no cli-console-timeout

Description
With this command, you disable the automatic logout.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no cli-console-timeout
82
Description
Time in seconds until automatic logout
after the last entry
no cli-console-timeout
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
60 ... 600
Default: 300
command.
show cli-console-timeout
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.