Security and authentication
11.4 IP access control list
Requirement
You are in the ACL standard configuration mode.
The command prompt is as follows:
cli(config-std-nacl)#
Syntax
Call up the command with the following parameters:
permit icmp {any | host <src-ip-address> | <src-ip-address> <src-mask>} [{any | host
<dest-ip-address> | <dest-ip-address> <dest-mask>}] [<message-type type(0-255)>]
[<message-code code(0-255)>]
The parameters have the following meaning:
Parameter
any
host
src-ip-address
src-ip-address
src-mask
any
host
dest-ip-address
dest-ip-address
dest-mask
message-type
type
message-code
code
Result
The IP access list for ICMP messages has been configured.
Note
Subnet mask for individual hosts
If you create the rule for a single system (one IPv4 address), specify the subnet mask
"255.255.255.255". As an alternative, you can specify the keyword "host" followed by the
IPv4 address.
844
Description
Allows all incoming frames
Keyword for a an individual IPv4 ad-
dress
Source IPv4 address
Network source address
Corresponding subnet mask
Allows all outgoing frames
Keyword for a an individual IPv4 ad-
dress
Destination IPv4 address
Network destination address
Corresponding subnet mask
Keyword for the ICMP message type
ICMP message type
Keyword for the ICMP message code
ICMP message code
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
-
-
Enter a valid IPv4 address.
Enter a valid combination of IPv4
address and subnet mask.
-
-
Enter a valid IPv4 address.
Enter a valid combination of IPv4
address and subnet mask.
-
0 ... 255
-
0 ... 255
Configuration Manual, 06/2016, C79000-G8976-C252-11