Parameter
FQDN
ipv6
ip6_addr
port
poll
seconds
secondary
Result
The SNTP unicast server is configured.
Further notes
You can reset the setting to the default with the
You display this setting and other information with the
command.
5.3.3.4

no sntp unicast-server

Description
With this command, you delete the attributes for an SNTP unicast server and reset the
address.
Requirement
You are in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
no sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <Fully Qualified Domain
Name(100)> | ipv6 <ip6_addr>}
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
Value for the IPv6 address of the time
server
UDP port of the time server
Keyword for the time after which the
time of day is requested again
Value for the time in seconds
Keyword to store the second SNTP
server
Range of values / note
Maximum of 100 characters
-
Enter a valid IPv6 address.
1025 ... 36564
Default: 123
-
16 ... 16284
If you do not specify this parame-
ter, the first SNTP server is
stored.
no sntp unicast-server