Configuring with Web Based Management
4.8 "Security" menu
device between two VPN endpoints, when there is inactivity, the connection is deleted
from its dynamic NAT table. To prevent this, keepalives are sent.
4.8.4.2

Remote End

On this WBM page, you configure the partner (VPN end point).
Description
The page contains the following:
● "Remote End Name" input box
Enter the name of the remote station and click "Create" to create a new remote station.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Name
Shows the name of the partner.
● Remote Mode
Specify the role the remote stations will adopt.
– Roadwarrior
– Standard
● Remote Type
Specify the type of remote station address.
– any (only with Roadwarrior)
– manual (With Roadwarrior)
160
In Roadwarrior mode, the device accepts VPN connections from partners with an
unknown address.
In standard mode, the device establishes a connection to or from a known remote
station. The remote station is identified by the IP address or the DDNS hostname.
Accepts the connection from remote stations with any IP address.
Only accepts connections from remote stations with a fixed IP address (/32), fixed IP
subnet (CIDR notation), or (D)DNS hostname.