Configuration
3.5 PoE
The user-defined power is compared to the range of values of the class indicated by the
connected device.
● If the user-defined power is within the class of the connected device, the user-defined
value is used.
● If the user-defined power is above the class of the connected device, the highest value of
the class is used.
● If the user-defined power is below the class of the connected device, the lowest value of
the class is used.
If the value used is exceeded, the device is turned off.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
poe pse <integer(1-4)> MaximumPower <integer(1-90)>
The parameters have the following meaning:
Parameter
integer
integer
Result
The value for the maximum power is configured.
Further notes
You delete the value for the parameter "Maximum Power" with the
command.
3.5.2.2

no poe pse MaximumPower

Description
With this command, you delete the value for the "Maximum Power" parameter.
130
Description
Number of the PSE
Value for the maximum power in watts
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
1 ... 4
1 ... 90
no poe pse MaximumPower
Configuration Manual, 06/2016, C79000-G8976-C252-11