No Arp Timeout - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
arp timeout <seconds(30-86400)>
The parameter has the following meaning:
Parameter
seconds
Result
The setting for the timeout setting of the ARP cache is configured.
Further notes
You can reset the timeout setting to the default with the
You can display the status of this function and other information with the
command.
7.12.2.4

no arp timeout

Description
With this command, you reset the timeout setting of the ARP cache back to the default value.
The default value for the timeout setting is 300 seconds.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no arp timeout
Result
The timeout setting for the ARP cache is reset to the default value.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Value for the timeout in seconds
Network protocols
Range of values /
note
30 ... 86400
Default: 300
command.
no arp timeout
show ip arp
7.12 ARP
427

Advertisement

Table of Contents
loading

Table of Contents