Siemens SCALANCE XM-400 Configuration Manual page 534

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Layer 3 functions
9.2 OSPFv2 (IPv4)
The parameters have the following meaning:
Parameter
area-id
router-id
authentication
hello-interval
retransmit-interval
transmit-delay
dead-interval
authentication-key
message-digest-key
key-id
Result
The virtual link is removed.
Further notes
You create virtual links with the
You display information about the virtual link with the
534
Description
Area-ID
ID of the router
Keyword for the authentication meth-
od of the virtual connection
Keyword for the interval at which
Hello packets are sent over the virtual
link
Keyword for the interval after which
packets whose receipt was not con-
firmed are transferred again.
Keyword for the time that a link state
update packet requires for transmis-
sion over the virtual link.
Keyword for the interval after which
the neighbor router is classified as
"failed" if Hello packets from it are not
received.
Keyword for the unencrypted pass-
word
Keyword for the ID of the password
ID of the password.
area virtual link
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Range of values / note
specify a valid ID.
x.x.x.x
x = 0 ... 255
0.0.0.0 = backbone area
-
simple
enables authentication using a
password
messagedigest
enables authentication using
MD5
none
no authentication
-
-
--
-
-
-
specify the ID
0 ... 255
command.
show ip ospf virtual
command.

Advertisement

Table of Contents
loading