Ping Ipv6 - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameters from the parameter list, the default values are used.
Result
The messages relating to the response of the called node are displayed.
3.1.10

ping ipv6

Description
With this command, you request a response from a device in the network. This allows you to
check whether or not another node is reachable.
Requirement
● IPv6 is enabled.
● You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
ping ipv6 <prefix%interface>
[repeat <count>]
[size <value>]
[anycast]
[source {vlan <id> | <source_prefix>}]
[timeout <value (1-100)>]
The parameters have the following meaning:
Parameter
prefix
%interface
repeat
count
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
or
cli#
Description
IPv6 address of the destination
optional parameter
Only necessary when the IPv6 ad-
dress of the destination is a link-local
address.
Keyword for the number of packets
to be requested
Number of packets
Configuration
3.1 System
Range of values / note
Enter a valid IPv6 address.
Specify the interface via which the
packet will be sent.
-
1 ... 10
Default: 5
79