Configuration
2.1 System
Syntax
Call the command without parameter assignment:
no alias
Result
The name of the interface is removed.
Further notes
You configure the name of the interface with the
2.1.10.3

duplex

Description
Electrical interfaces can be operated in full duplex mode or half duplex mode. The options
here depend on the connected device.
Optical connections are always operated in full duplex mode since they have a fiber for each
transmission direction.
With this command, you configure the duplex mode of an interface. The same mode must be
set for connected interfaces.
Requirement
● Autonegotiation is disabled.
● You are in the Interface configuration mode of an electrical interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
duplex {full|half}
The parameters have the following meaning:
Parameter
full
half
60
Description
The Interface will be operated in full
duplex mode.
The Interface will be operated in half
duplex mode
command.
alias
Range of values / note
Default:
full
-
SCALANCE S615 Command Line Interface