Events; Configuration - Siemens SIMATIC NET SCALANCE S615 Configuration Manual

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Configuring with Web Based Management
4.4 "System" menu
4.4.5

Events

4.4.5.1

Configuration

Selecting system events
On this WBM page, you specify which system events are logged and how.
The following messages are always entered in the event log table and cannot be deselected:
● Changing the admin password
● Starting the device
● Operational status of the device, e.g. whether or not a PLUG is inserted.
● Status of errors not yet dealt with
To send messages additionally to a syslog server, enable the "Syslog" setting.
Description
Table 1 has the following columns:
● Event
Shows that the settings are valid for all events of table 2.
● E-Mail / Trap / Log Table / Syslog / Fault / Digital Out / VPN Tunnel
Enable or disable the required type of notification for all events. If "No Change" is
selected, the entries of the corresponding column in Table 2 remain unchanged.
● Copy to Table
If you click the button, the setting is adopted for all events of table 2.
76
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02