No Ip Route - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

The parameter has the following meaning:
Parameter
prefix
mask
next-hop
distance
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The entry in the IP routing table is configured.
Further notes
You delete an entry from the IP routing table with the
You display the IP routing table with the
6.1.2.6

no ip route

Description
With this command, you delete a static entry from the IP routing table.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no ip route <prefix> <mask> <next-hop> [<distance(1-255)>]
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
Description
Specifies the IP address or the address
range
Specifies the subnet mask used for
.
prefix
Use decimal notation.
Specifies the IP address to which the
selected addresses will be forwarded.
The value for the administrative dis-
tance.
show ip route
Network protocols
6.1 IPv4 protocol
Range of values / note
specify a valid IP address
enter a valid subnet mask
specify a valid IP address
1 ... 255
command.
no ip route
command.
179

Hide quick links:

Advertisement

Table of Contents
loading