Section 1.2

Ports, Controls and Indicator LEDs

The RX1100 features various ports, controls and indicator LEDs on the front panel for configuring and
troubleshooting the device.
Figure 1: Front Panel
1. Port Status Indicator LEDs
LEDs
6. RS232 Serial Console Port (RJ45)
Port Status Indicator LEDs
Display Mode Indicator LEDs
Mode button
Alarm Indicator LED
Power Module Indicator LEDs
RS232 Serial Console Port
Ports, Controls and Indicator LEDs
1
2. Display Mode Indicator LEDs
These LEDs indicate the state of each port.
• Green (Solid) = Link detected
• Green (Blinking) = Link activity
• Off = No link detected
These LEDs indicate the current display mode for the port status indicator LEDs (i.e. PPP-
DATA, PPP-LINK or GPS LOCK).
The Mode button sets the display mode for the port status indicator LEDs (i.e. PPP-DATA,
PPP-LINK or GPS LOCK). It can also be used to reset the device if held for 5 seconds.
The alarm indicator LED illuminates when an alarm condition exists.
These LEDs indicate the status of the power modules.
• Green = The power supply is supplying power
• Red = Power supply failure
• Off = No power supply is installed
This port is for interfacing directly with the device and accessing initial management