Serial Communications Controllers
Bits
Name
11–12
TPP
Tx preamble pattern. Determines what, if any, bit pattern should precede each Tx frame. The preamble
pattern is sent before the first flag/sync of the frame. TPP is ignored in UART mode. The preamble length
is programmed in TPL; the preamble pattern is typically sent to a receiving station that uses a DPLL for
clock recovery. The receiving DPLL uses the regular preamble pattern to help it lock onto the received
signal in a short, predictable time period.
00 All zeros
01 Repetitive 10s. Select this setting for Ethernet operation.
10 Repetitive 01s
11 All ones. Select this setting for LocalTalk operation.
13
TEND
Transmitter frame ending. Intended for NRZI transmitter encoding of the DPLL. TEND determines
whether TXD should idle in a high state or in an encoded ones state (high or low). It can, however, be
used with other encodings besides NRZI.
0 Default operation. TXD is encoded only when data is sent, including the preamble and opening and
closing flags/syncs. When no data is available to send, the signal is driven high.
1 TXD is always encoded, even when idles are sent.
14–15
TDCR
Transmitter/receiver DPLL clock rate. If the DPLL is not used, choose 1× mode except in asynchronous
UART mode where 8×, 16×, or 32× must be chosen. TDCR should match RDCR in most applications to
16–17
RDCR
allow the transmitter and receiver to use the same clock source. If an application uses the DPLL, the
selection of TDCR/RDCR depends on the encoding/decoding. If communication is synchronous, select
1×. FM0/FM1, Manchester, and Differential Manchester require 8×, 16×, or 32×. If NRZ- or
NRZI-encoded communication is asynchronous (that is, clock recovery required), select 8×, 16×, or 32×.
The 8× option allows highest speed, whereas the 32× option provides the greatest resolution.
00 1× clock mode. Only NRZ or NRZI encodings/decodings are allowed.
01 8× clock mode
10 16× clock mode. Normally chosen for UART and AppleTalk.
11 32× clock mode
18–20
RENC
Receiver decoding/transmitter encoding method. Select NRZ if DPLL is not used. RENC should equal
TENC in most applications. However, do not use this internal DPLL for Ethernet.
21–23
TENC
000 NRZ (default setting if DPLL is not used). Required for UART (synchronous or asynchronous).
001 NRZI Mark (set RINV/TINV also for NRZI space).
010 FM0 (set RINV/TINV also for FM1).
011 Reserved
100 Manchester
101 Reserved
110 Differential Manchester (Differential Bi-phase-L)
111 Reserved