RM0400
Field
ATOM Channel Slope Selection 1. The TSS1 field selects the slope for the ATOM selected channel.
00 Any transition (both)
29–28
01 Transition from 0 to 1 (positive slope)
TSS1
10 Transition from 1 to zero (negative slope)
11 Reserved
ATOM sub-module Source Selection 1. Selects which ATOM sub-module is the source for
watchpoint generation.
0000 ATOM0
0001 ATOM1
0010 ATOM2
0011 Reserved
0100 Reserved
0101 Reserved
27–24
0110 Reserved
SSEL1
0111 Reserved
1000 Reserved
1001 Reserved
1010 Reserved
1011 Reserved
1100 Reserved
1101 Reserved
1110 Reserved
1111 Reserved
Halt Enable 1. The HEN1 Halt Enable 1 bit controls if the selected ATOM Channel is used to halt
the GTM module. If this bit is set and an event occurs on the selected ATOM Channel filter output,
23
a Halt signal is generated to the GTM which enters debug state.
HEN1
0 Disables Halt GTM
1 Enables Halt GTM
Watchpoint Message Control 1. The WMC1 Watchpoint Message Control 1 bit controls the
watchpoint message sent through the Message Data bus. If this bit is set it enables valid transitions
on the selected ATOM Channel output to generate a watchpoint message. This bit is written by the
22
JTAG interface but can also be controlled at SoC level with dedicated Start/Stop signals inputs to
WMC1
GTMDI.
0 Watchpoint Messages disabled
1 Watchpoint Messages enabled
ATOM channel selection 1. Selects which channel in an ATOM module generates watchpoints.
000
ATOM CH0
001
ATOM CH1
010
ATOM CH2
18–16
011
ATOM CH3
CHSEL1
100
ATOM CH4
101
ATOM CH5
110
ATOM CH6
111
ATOM CH7
ATOM Channel Slope Selection 2. The TSS2 field selects the slope for the ATOM selected channel.
00 Any transition (both)
13–12
01 Transition from 0 to 1 (positive slope)
TSS2
10 Transition from 1 to zero (negative slope)
11 Reserved
Table 466. GTMDI_ATOM_WPC1 field descriptions
DocID027809 Rev 4
GTM Development Interface (GTMDI)
Description
895/2058