SENT Receiver (SRX)
49.3.2.6
Data Control Register 1 (DATA_CTRL1)
The Data Control Register 1 (DATA_CTRL1) is described below.
Address Offset = 0x0018
0
R
W
Reset
0
8
R
W
Reset
0
16
R
W
Reset
0
24
R
W
Reset
0
Field
0
Reserved for future use. Reads returns zeros.
Number of Data Nibbles supported in Channel 0
1:3
NIBBCH0
0 and 7 – Invalid value. Must not be used
1 to 6 – Number of data nibbles to be supported by respective channel
4
Reserved for future use. Reads returns zeros.
Number of Data Nibbles supported in Channel 1
5:7
NIBBCH1
0 and 7 – Invalid value. Must not be used
1 to 6 – Number of data nibbles to be supported by respective channel
8
Reserved for future use. Reads returns zeros.
Number of Data Nibbles supported in Channel 2
9:11
NIBBCH2
0 and 7 – Invalid value. Must not be used
1 to 6 – Number of data nibbles to be supported by respective channel
1374/2058
1
2
NIBBCH0
0
0
9
10
NIBBCH2
0
0
17
18
NIBBCH4
0
0
25
26
NIBBCH6
0
0
Figure 783. Data Control Register 1 (DATA_CTRL1)
Table 795. DATA_CTRL1 field descriptions
DocID027809 Rev 4
3
4
1
0
11
12
1
0
19
20
1
0
27
28
1
0
Description
Access: RW
5
6
NIBBCH1
0
0
13
14
NIBBCH3
0
0
21
22
NIBBCH5
0
0
29
30
NIBBCH7
0
0
RM0400
7
1
15
1
23
1
31
1
Need help?