Command Reference Guide
ip sip timer rollover register
Use the ip sip timer rollover register command to specify the time period (in seconds) that the Session
Initiation Protocol (SIP) proxy waits for a response to a REGISTER request before attempting to find an
alternate destination. Use the no form of this command to return to the default value. Variations of this
command include:
ip sip timer rollover register <value>
ip sip timer rollover register follow-primary
Syntax Description
<value>
follow-primary
Default Values
By default, the rollover timer for REGISTER events is set to follow-primary.
Command History
Release 18.2
Usage Examples
The following example allows REGISTER request attempts to continue without response for up to 32
seconds before rolling over to another destination:
(config)#ip sip timer rollover register 32
60000CRG0-35E
Specifies the rollover time period for REGISTER events in seconds. Range
is 1 to 32 seconds.
Links the rollover timer for REGISTER events to the primary rollover timer
specified by the ip sip timer rollover
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
Global Configuration Mode Command Set
command.