Command Reference Guide
clock source
Use the clock source command to configure the source timing used for the interface. The clock specified
using the clock source command is also the system master clock. Use the no form of this command to
return to the default value. Variations of this command include:
clock source internal
clock source line
Syntax Description
internal
line
Default Values
By default, the clock source is set to line.
Command History
Release 1.1
Functional Notes
When operating on a DDS network, the clock source should be line. On a point-to-point private network,
one unit must be line and the other internal.
Usage Examples
The following example configures the unit to recover clocking from the circuit:
(config)#interface dds 1/1
(config-dds 1/1)#clock source line
60000CRG0-35E
Configures the unit to provide clocking using the internal oscillator.
Configures the unit to recover clocking from the digital data service (DDS)
circuit.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.