Command Reference Guide
line-length <value>
Use the line-length command to set the line build out (LBO) (in feet or dB) for the DSX-1 interface. Use
the no form of this command to return to the default value.
Syntax Description
<value>
Default Values
LBO
By default, the
is set to 0 feet.
Command History
Release 1.1
Functional Notes
The line-length value represents the physical distance between DSX equipment (measured in cable
length). Based on this setting, the AOS device increases signal strength to compensate for the distance
the signal must travel. Valid distance ranges are listed below:
•
0 to 133 feet
•
134 to 265 feet
•
266 to 399 feet
•
400 to 533 feet
•
534 to 655 feet
Usage Examples
The following example configures the DSX-1 interface line-length for 300 feet:
(config)#interface t1 1/2
(config-t1 1/2)#line-length 300
60000CRG0-35E
LBO
Configures the
for the DSX-1 interface. Valid options include: -7.5 dB
or 0 to 655 feet. Use the -7.5 dB option for maximum attenuation.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
DSX-1 Interface Command Set
1569