ADTRAN AOS Version R10.1.0 Command Reference Manual page 1610

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
ethernet-cfm mep
Use the ethernet-cfm mep command to create an Ethernet operations, administration, and maintenance
(OAM) connectivity fault management (CFM) maintenance endpoint (MEP) on the Ethernet interface. Use
the no form of this command to remove the MEP from the interface. Variations of this command include:
ethernet-cfm mep <name> <name> <mep id> down
ethernet-cfm mep none <name> <mep id> down
Syntax Description
<name>
<name>
<mep id>
none
down
Default Values
By default, no MEPs exist on the interface.
Command History
Release 17.4
Release A4.01
Functional Notes
For more information about Ethernet OAM CFM and its operation on AOS products, refer to the Ethernet
OAM CFM in AOS configuration guide available online at
3013).
For more information about specific MEP configuration commands, refer to the
Command Set on page
Usage Examples
The following example creates an MEP, with the MEP ID 100, on Ethernet interface eth 0/1. The MEP is
associated with maintenance domain Domain1 and association association1:
(config)#interface eth 0/1
(config-eth 0/1)#ethernet-cfm mep Domain1 association1 100 down
(config-eth 0/1-mep)
60000CRG0-35E
Specifies the MEP's maintenance domain.
Specifies the MEP's maintenance association.
Specifies the unique numerical ID for this MEP. Range is 1 to 8191.
Optional. Specifies no domain name is used.
Specifies the direction of the MEP.
Command was introduced.
Command was expanded to include the Metro Ethernet Forum (MEF)
Ethernet Interface.
3091.
Copyright © 2012 ADTRAN, Inc.
Ethernet Interface Command Set
https://supportforums.adtran.com
Ethernet OAM CFM