Command Reference Guide
probe responder
Use the probe responder command to enable a probe responder to respond to specific probe packets.
Additional commands for each responder type are covered in
Command Set on page
responding to the specific probe packets. Variations of this command include:
probe responder icmp-timestamp
probe responder twamp
probe responder udp-echo
Issue the no shutdown command to activate the probe responder once it is configured.
Syntax Description
icmp-timestamp
twamp
udp-echo
Default Values
By default, there are no probe responders enabled.
Command History
Release 17.2
Usage Examples
The following example enables the UDP echo probe responder:
>enable
#configure terminal
(config)#probe responder udp-echo
(config-probe-probe1)#
60000CRG0-35E
2966. Use the no form of this command to stop the probe responder from
Specifies the probe responder type as Internet Control Message Protocol
(ICMP) timestamp.
Specifies the probe responder type as Two-Way Active Measurement
Protocol (TWAMP).
Specifies the probe responder type as a User Datagram Protocol (UDP)
echo.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
Global Configuration Mode Command Set
Network Monitor Probe Responder
1293