ADTRAN AOS Version R10.1.0 Command Reference Manual page 1234

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
Global Configuration Mode Command Set
Functional Notes
Once a device receives data from a neighboring device in an LLDP frame, it will retain that data for a
limited amount of time. This amount of time is called time to live, and it is part of the data in the LLDP
frame. The time to live transmitted in the LLDP frame is equal to the transmit interval multiplied by the TTL
multiplier.
Usage Examples
The following example sets the LLDP minimum transmit interval to 10 seconds:
(config)#lldp minimum-transmit-interval 10
The following example sets the LLDP reinitialization delay to 5 seconds:
(config)#lldp reinitialization-delay 5
The following example sets the LLDP transmit interval to 15 seconds:
(config)#lldp transmit-interval 15
The following example sets the LLDP transmit interval to 15 seconds and the TTL multiplier to 2 for all
LLDP frames transmitted from the unit. The resulting TTL is 30 seconds:
(config)#lldp transmit-interval 15
(config)#lldp ttl-multiplier 2