ADTRAN AOS Version R10.1.0 Command Reference Manual page 1557

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
clock rate
Use the clock rate command to configure the data rate used as the operating speed for the interface. This
rate should match the rate required by the digital data service (DDS) service provider. Use the no form of
this command to return to the default value. Variations of this command include:
clock rate auto
clock rate bps56k
clock rate bps64k
Syntax Description
auto
bps56k
bps64k
Default Values
By default, the rate is set to auto.
Command History
Release 1.1
Functional Notes
When operating at 64 kbps (clear channel operation), the data terminal equipment (DTE) data sequences
may mimic network loop maintenance functions and erroneously cause other network elements to activate
loopbacks. Use the data-coding scrambled command to prevent such occurrences. Refer to
scrambled on page 1559
Usage Examples
The following example configures the clock rate for 56 kbps operation:
(config)#interface dds 1/1
(config-dds 1/1)#clock rate bps56k
60000CRG0-35E
Automatically detects the clock rate and sets to match.
Sets the clock rate to 56 kbps.
Sets the clock rate to 64 kbps.
Command was introduced.
for related information.
Copyright © 2012 ADTRAN, Inc.
DDS Interface Command Set
data-coding
1557

Advertisement

Table of Contents
loading

Related Products for ADTRAN AOS Version R10.1.0

This manual is also suitable for:

Aos r10.1.0

Table of Contents