ADTRAN AOS Version R10.1.0 Command Reference Manual page 1573

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
signaling-mode
Use the signaling-mode command to configure the signaling type (robbed-bit for voice or clear channel
for data) for the level zero digital signals (DS0s) mapped to the DSX-1 port. Use the no form of this
command to return to the default setting. Variations of this command include:
signaling-mode message-oriented
signaling-mode none
signaling-mode robbed-bit
Syntax Description
message-oriented
none
robbed-bit
Default Values
By default, the signaling mode is set to robbed-bit.
Command History
Release 1.1
Usage Examples
The following example configures the DSX-1 port for PRI compatibility:
(config)#interface t1 1/2
(config-t1 1/2)#signaling-mode none
60000CRG0-35E
Specifies clear channel signaling on Channel 24 only. Use this signaling
type with QSIG installations.
Specifies clear channel signaling on all 24 DS0s. Use this signaling type
with data-only or primary rate interface (PRI) DSX-1 installations.
Specifies robbed bit signaling on all DS0s. Use this signaling type for
voice-only DSX-1 applications.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
DSX-1 Interface Command Set
1573