ADTRAN AOS Version R10.1.0 Command Reference Manual page 1406

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
voice flashhook threshold <min time> <max time>
Use the voice flashhook threshold command to configure the minimum and maximum time the switch
hook must be held to be interpreted as a flash. Use the no form of this command to return to the default
setting.
Syntax Description
<min time>
<max time>
Default Values
By default, the flashhook threshold times are 300 milliseconds (minimum) and 1000 milliseconds
(maximum).
Command History
Release 9.3
Usage Examples
The following example configures the flashhook thresholds at a minimum of 400 to a maximum of 900:
(config)#voice flashhook threshold 400 900
60000CRG0-35E
Specifies minimum flashhook time in milliseconds. Valid range is from
300 to 1000 milliseconds.
Specifies maximum flashhook time in milliseconds. Valid range is from
300 to 1000 milliseconds.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.