ADTRAN AOS Version R10.1.0 Command Reference Manual page 1370

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
Global Configuration Mode Command Set
Default Values
The default values for this command are as follows:
thresholds BES 15Min 10
thresholds BES 24Hr 100
thresholds CSS 15Min 1
thresholds CSS 24Hr 4
thresholds DM 15Min 1
thresholds DM 24Hr 4
thresholds ES 15Min 65
thresholds ES 24Hr 648
thresholds LCV 15Min 13340
thresholds LCV 24Hr 133400
thresholds LES 15Min 65
thresholds LES 24Hr 648
thresholds PCV 15Min 72
thresholds PCV 24Hr 691
thresholds SEFS 15Min 2
thresholds SEFS 24Hr 17
thresholds SES 15Min 10
thresholds SES 24Hr 100
thresholds UAS 15Min 10
thresholds UAS 24Hr 10
Command History
Release 11.1
Command was introduced.
Usage Examples
The following example sets the threshold for the 15-minute and 24-hour bursty errored seconds counter to
25 and 200, respectively:
(config)#thresholds BES 15Min 25
(config)#thresholds BES 24Hr 200