power inline
Use the power inline command to detect attached powered devices (PDs) and deliver 48 VDC, compliant
with the IEEE 802.3af Power over Ethernet (PoE) standard, to the PD via existing CAT 5 cabling. To
disable power detection and supply, use the power inline never command. Variations of this command
include:
power inline auto
power inline legacy
power inline never
power inline 2-point
Syntax Description
auto
legacy
never
2-point
Default Values
By default, PWR switches discover and provide power to IEEE-compliant PDs.
Command History
Release 9.1
Release A4.01
Usage Examples
The following example configures the Ethernet interface to detect and supply power to PDs:
(config)#interface ethernet 0/3
(config-eth 0/3)#power inline auto
60000CRG0-35E
Enables power detection and supply to PDs.
Enables power detection and supply of legacy non-IEEE 802.3af-compliant
PDs.
Disables power detection and supply to PDs.
Enables power detection and supply using the 2-point detection method
necessary for some PDs.
Command was introduced.
Command was expanded to include the 2-point parameter.