impedance
Use the impedance command to configure the alternating current (AC) impedance of the 2-wire interface.
Use the no form of this command to return to the default value. Variations of this command include:
impedance 600c
impedance 600r
impedance 900b
impedance 900c
impedance 900r
impedance z1
impedance z2
impedance z3
impedance z4
impedance z5
impedance z6
impedance z7
Syntax Description
600c
600r
900b
900c
900r
z1
z2
z3
z4
z5
z6
z7
Default Values
The default value for this command is 600r.
Command History
Release 6.1
Release A1
Release A2
Release A4.03
60000CRG0-35E
Specifies an impedance of 600
Specifies an impedance of 600
Use only when directed by ADTRAN and only with part number 1203602L1.
Specifies an impedance of 900
Specifies an impedance of 900
Specifies an impedance of Rs 220 W, Rp 820 W, Cp 115 nF.
Specifies an impedance of Rs 270 W, Rp 750 W, Cp 150 nF.
Specifies an impedance of Rs 270 W, Rp 750 W, Cp 150 nF, Zin 600r.
Specifies an impedance of Rs 320 W, Rp 1050 W, Cp 230 nF.
Specifies an impedance of Rs 350 W, Rp 1000 W, Cp 210 nF, Zin 600r.
Specifies an impedance of Rs 370 W, Rp 620 W, Cp 310 nF.
Specifies an impedance of Rp 800 W, Rs 100 W, Cs 50 nF.
Command was introduced.
Command was expanded to include the 900b impedance setting.
Command was expanded to include the z1 impedance setting.
Command was expanded to include the z2, z3, z4, z5, z6, and z7
impedance settings.