Common low ERL values are between 5 and 8 dB. Acceptable ERL values begin around 12 dB. The
higher the ERL value, the more gain adjustment can be made without introducing echo. The commonly
recommended configuration is a receive gain of 0 dB and a ttransmit gain of +6 dB.
The following is an error that could result by attempting to measure ERL when a measurement sequence is
already active:
% could not run erl test
During test execution, a warning is issued when a test sequence terminates abnormally. Reasons for early
termination include:
Was not able to seize the line
Line disconnected during test
DSP timeout (i.e., when the DSP hardware version does not support this feature)
Test runs for more than 20 seconds per impedance value (for example, 80 seconds with a 4 impedance
setting)
Usage Examples
The following example tests the FXO interface 0/1 to automatically find the best measured impedance
settings:
(config)#interface fxo 0/1
(config-fxo 0/1)#test erl all auto-set
The following example displays the ERL test status (the output is shown after the command):
(config)#interface fxo 0/1
(config-fxo 0/1)#test erl display-results
Port
Impedance
--------------------------------------------------------------------------------------------------------
fxo 0/1
600 c
fxo 0/1
900 r
fxo 0/1
900 c
fxo 0/1
z1
fxo 0/1
z2
fxo 0/1
z3
fxo 0/1
z4
fxo 0/1
z5
60000CRG0-35E
Status
Measured ERL
10 dB
8 dB
9 dB
13 dB
11 dB
14 dB
12 dB
test calling