inband-protocol
Use the inband-protocol command to designate the inband loopback pattern to send/detect on the
single-pair high-speed digital subscriber line (SHDSL) interface. Use the no form of this command to
return to the default setting. Variations of this command include:
inband-protocol pn127
inband-protocol v54
Syntax Description
pn127
v54
Default Values
By default, the inband loopback pattern is set to v54.
Command History
Release 4.1
Functional Notes
Inband loopbacks are specific patterns that are sent in place of user data to trigger a loopback. Both
PN127 and V.54 are industry standard loopback patterns used to allow remote loopbacks.
Usage Examples
The following example sets the inband loopback pattern for pn127:
(config)#interface shdsl 1/1
(config-shdsl 1/1)#inband-protocol pn127
60000CRG0-35E
Selects PN127 as the inband loopback pattern to send/detect.
Selects V.54 as the inband loopback pattern to send/detect.
Command was introduced.