Note:
The data will be encrypted even if you do not transmit the safety certificate to
your working environment.
Since the safety exception rule was saved permanently in the Mozilla Firefox,
for example, no more safety warnings will be provided after accessing the
PBX.
4. Click with wizard (recommended).
The configuration manager opens.

Commissioning Analogue End Devices

Requirements:
• Internal number configured on the a/b port in question (see chapter Settings > Internal
Telephone Numbers > Creating Analogue Subscribers)
• PBX connected to earthing (see chapter Installation and Commissioning > Preparation
(COMpact 4000) > Connecting to Earthing)
1. Connect end devices with a separate power supply to the mains.
The end device is ready for operation.

Commissioning Standard ISDN End Devices

Requirements:
• Internal number configured on the S
Telephone Numbers > Creating ISDN Subscribers)
• PBX connected to earthing (see chapter Installation and Commissioning > Preparation
(COMpact 4000) > Connecting to Earthing)
1. Connect end devices with a separate power supply to the mains.
2. Enter the internal number as an MSN for the end device.
COMpact 4000 - Firmware V6.6A - Installation, Operation and Configuration V03 03/2016
port in question (see chapter Settings > Internal
0
Installation and Commissioning
Commissioning
Commissioning Analogue End Devices
95