Auerswald COMpact 4000 Operation Manual page 82

Pbx for analogue/isdn/internet telephony
Hide thumbs Also See for COMpact 4000:
Table of Contents

Advertisement

Installation and Commissioning
ISDN End Devices
Connecting the Cable and the Wall Sockets to the Internal S
Note: When assigning the individual wires, orient yourself with the identifiers
subsequently listed or refer to VDE 0815 when identifiers deviate.
Physical circuit/
pair 1
Physical circuit/
pair 2
3. Connect the IAE or UAE8 sockets to the terminal clamps at the internal S
The figure below shows the wiring of the terminal clamps with different wall sockets
(IAE and UAE8) in a diagram, as well as the position of the terminators in the last wall
socket.
4. Equip the last wall socket with two terminators.
82
Port (Internal S
0
Cable with Two
Twin Wires
a1
red
b1
black
a2
white
b2
yellow
COMpact 4000 - Firmware V6.6A - Installation, Operation and Configuration V03 03/2016
Bus)
0
Cable with Star Quad
without ring
single rings, 17 mm spacing
double rings, 34 mm spacing
double rings, 17 mm spacing
port.