Switching Authorisation For Switching Of Relays On/Off - Auerswald COMpact 4000 Operation Manual

Pbx for analogue/isdn/internet telephony
Hide thumbs Also See for COMpact 4000:
Table of Contents

Advertisement

Proceed as follows:
• Separately for relays
• Using the configuration manager
Requirements:
• Created analogue relay
1. Open the page Devices > Relays (Actuators).
2. Click Configure in the line for the corresponding relay.
3. Enter DTMF sequences required by the connected device in the Switch on and
Switch off entry fields. Possible entries:
Digits and the characters * and #
The comma ',' character as a pause of half a second

Switching Authorisation for Switching of Relays On/Off

If the authorisation for switching of relays is enabled, the subscriber in question can switch
relays manually.
Proceed as follows:
• Separately for subscribers
• Separately for configurations
• Using the configuration manager
Note: As described in the following, the setting is also possible via profiles
(Subscriber (scr.) > Profiles > Configuration > Configure > Auhtorisa-
tions). If the check box Profile-controlled settings has been selected, the
property set in the right-hand column will apply. For assignment of the profile,
see chapter Settings > Profiles.
1. Open the page Subscriber (scr.) > Properties > Authorisations.
2. In the list field at the top, select the subscriber in question by his name or number.
COMpact 4000 - Firmware V6.6A - Installation, Operation and Configuration V03 03/2016
Switching Authorisation for Switching of Relays On/Off
Functions
Relays (Actuators)