I/O List (Sensor); Models Of Sensors And Parts Codes - FujiFilm CR-IR341 Service Manual

Fuji computed radiography
Table of Contents

Advertisement

1
2
C
ONTENTS
5.2

I/O List (Sensor)

Unit
Symbol
Cassette set
SA2, 6, 10, 14
unit (A)
SA4, 8, 12, 16
SA3, 7, 11, 15
SA1, 5, 9, 13
SA17
IP
SB1
removal unit
SB2
(B)
SB3
SB4
SB5
Before-side-
SC1
SC2
positioning
conveyor (C)
Side-
SD1
positioning
conveyor (D)
SD2
SD3
BCR
After-reading
SE1
conveyor (E)
Erasure
SF1
conveyor (F)
SF2
SF3
SF4
TSW1
TSW2
LDSN1-1, 2, 3, 4, 5
Subscanning
SZ1 (SED08A)
unit (Z)
SZ2
SZ3

5.2.1 Models of Sensors and Parts Codes

Code No.
MS/PS
104N0043
PS
104N0044
PS
104Y0162
PS
113Y1038
PS
113Y1395
PS
128S0392
Suction sensor
128Y0241A
MS
128Y0258B
MS
009-051-04
05.31.99 FM2460
3
4
5
6
Panel display
Name
When the cassette
Cassette IN sensor
has been inserted
with the cassette
hold sensor OFF:
ON (1)
Mammo/ST sensor
For mammo
cassette: ON (1)
Cassette hold sensor
During cassette
hold:
Cassette ejection sensor
During cassette
eject: OFF (0)
Elevation HP sensor
During HP: ON (1)
During HP: ON (1)
Suction cup HP sensor
IP found: ON (1)
Cassette inlet IP sensor
When located in
the shelf position:
ON (1)
IP found: ON (1)
Each shelf position sensor
Inch/metric sensor
During IP suction:
Suction sensor
ON (1)
IP found: ON (1)
Before-BCR IP sensor
IP found: ON (1)
Convergence standby
IP sensor
Side-positioning
During HP: ON (1)
mechanism HP sensor
During HP: ON (1)
Grip release HP sensor
Side-positioning HP sensor
IP found: ON (1)
Barcode reader
Grip release HP sensor
During HP: (1)
After-reading conveyance
IP found: ON (1)
standby IP sensor
Changeover IP sensor
IP found: ON (1)
Load standby IP sensor
IP found: ON (1)
Overrun IP sensor
IP found: ON (1)
Safety thermostat
Safety thermostat
Unlit lamp sensor
IP leading-edge sensor
IP found: ON
(no display)
Driving-side grip release
During HP: ON (1)
HP sensor
During HP: ON (1)
Driven-side grip release
HP sensor
Model
OJ-380331-701 (5mm Type I)
OJ-380331-702 (5mm Type L) SA3, 7, 11, 15, 17, SB3, SD1
Separation type
19mm Type I
Reflective type
MPL-503(MPL)
SS-01GL111
SS-01GL2-F + mount
CR-IR341 Service Manual
7
8
9
10
Type
MS
Recognizes the status in pair with SA3, 7, 11,
and 15
Detects mammo and ST cassette types.
MS
Detects the completion of cassette hold.
PS
Detects that the cassette has been ejected.
PS
Elevation HP for suction conveyor.
PS
PS
PS
IP conveyance sensor
PS
IP width determination
PS (reflective
type)
Suction sensor
PS
IP conveyance sensor
IP conveyance sensor
PS
PS
PS
PS
IP conveyance sensor
Variation or option
PS
IP conveyance sensor
PS
IP conveyance sensor
PS
IP conveyance sensor
PS
IP conveyance sensor
PS
(separation
type)
Lamp house
Fan control
PS (light-
IP conveyance sensor
receiving type)
PS
PS
Relevant sensor symbols
SA1, 5, 9, 13, SB1, SD2, SE1, SZ2, 3
SF4
SB2, SC1, 2, SD3, SF1, 2, 3
SB4
SB5
SA2, 6, 8, 10
SA4, 8, 12, 16
MD - 15
Function/Remarks
TR1H1003.EPS
TR1H1150.EPS
MD - 15