Tensioner Not Requiring Tension Adjustment - FujiFilm CR-IR341 Service Manual

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
3.4

Tensioner Not Requiring Tension Adjustment

For a timing belt that needs to be replaced during removal of a unit, a tensioner that permits
the tension to be automatically adjusted by the spring force is employed.
Procedures for removing the timing belt
(1) Loosen the tensioner retaining screw.
The tensioner becomes movable.
(2) With the tensioner pushed to the loosened screw, secure it in place by tightening the
screw.
(3) Remove the timing belt.
FRONT
positioning conveyor
009-051-04
05.31.99 FM2460
3
4
5
6
Vertical conveyor
Before-side-
Erasure conveyor
CR-IR341 Service Manual
7
8
9
10
Loosen
screw
Timing belt
Erasure conveyor
MD - 9
Vertical conveyor
Timing belt
Tensioner
Before-side-
positioning
conveyor
Tensioner
Loosen
screw
Before-side-
positioning conveyor
FR1H1226.EPS