FujiFilm CR-IR341 Service Manual page 728

Fuji computed radiography
Table of Contents

Advertisement

C
11
12
ONTENTS
Replacement
(1) Remove the erasure conveyor.
"12.2 Removal and Reinstallation of Erasure Conveyor"
(2) Remove MF1.
"12.7 Replacing IP Transport Motor (MF1)"
(3) Remove the timing belt.
(4) Attach a new erasure unit IP conveyance timing belt.
(5) Adjust the tension.
" Adjustment"
Spacer
009-051-04
05.31.99 FM2460
13
14
15
16
(2)
Timing belt wheel
Hex socket head bolt
M4x20
(3)
Timing belt
CR-IR341 Service Manual
Erasure conveyor
MC - 237
FR1H1271.EPS
MC - 237

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents