FujiFilm CR-IR341 Service Manual page 89

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
7.4
Side-Positioning Conveyor
Barcode Reader (BCR) Reading
After the width/length of the IP is determined, the IP is conveyed to the side-positioning
conveyor. The IP No. is read by the barcode reader (BCR) from the IP being conveyed. For
an IP size of 14"x 17" or 14" x 14", the leading edge of the IP has moved beyond the side-
positioning top stopper and reached before the subscanning unit; as such, after reading by
the barcode reader, reverse conveyance of the IP is performed to move the latch assembly
by 9.6 mm (64 pulses) from the home position and move up the side-positioning top stopper.
For IP sizes other than 14"x 17" or 14" x 14", reverse conveyance of the IP is not performed;
instead, after reading by the barcode reader, the side-positioning top stopper is moved up.
Up/down operation of side-positioning top stopper
Side-positioning top stopper
(UP condition)
Guide plate
009-051-04
05.31.99 FM2460
3
4
5
6
Barcode reader (BCR) mounting position
REAR
MD1
FRONT
CR-IR341 Service Manual
7
8
9
10
BCR
Side-positioning
mechanism (shuttle)
FR1H0215.EPS
Latch assembly
Side-positioning top stopper
Latch assembly
Side-positioning top stopper
Side-positioning top stopper
MD - 26
Guide of side-positioning top stopper
Guide plate
Shaft
Shaft
Side-positioning top stopper
UP condition
(as seen from right)
Guide of side-positioning top stopper
Guide plate
Shaft
DOWN condition
(as seen from right)
FR1H0216.EPS
MD - 26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents