(6) Remove the spur gear, two spacers, two slide bearings, and E-ring from the cleaning
roller.
Spur gear
Sems M3x10
(7) Install the spur gear, two spacers, two slide bearings, and E-ring removed at step (6)
to a new cleaning roller.
(8) Reinstall the cleaning roller to the cleaning roller assembly.
(9) Reinstall the cleaning roller assembly in reverse order of removal.
009-051-04
05.31.99 FM2460
3
4
5
6
(6)
Cleaning roller
Slide bearing
Spacer
CR-IR341 Service Manual
7
8
9
10
E-ring
Slide bearing
FR1H1442.EPS
MC - 98
MC - 98