Error Handling: Recovered IP Load
(1) Overall/General Sequence
This process is performed when any IP error is detected before side-positioning conveyance.
Reverse conveyance load is performed to return the error IP to the cassette.
Corresponding sequences
Fig. 2.5.3 IP Determination
Fig. 2.6.2 BCR
Fig. 2.6.6 CSL/IDT Information Check
At the time when the error
IP is returned to the cassette,
an elevation permission is
issued to start the processing
for the next IP in the queue.
At the same time, removal of
the cassette for the error IP
is notified to the user.
Table 6.3.1 Operation Parameters
Description
Symbol
PB14
Suction cup movement (HP
load standby)
Wait for cassette OUT
TA13
Table 6.3.1a List of I/O Names Used in the Flow and Drawing
I/O name
Topmost
I/O name
2nd shelf
3rd shelf
shelf
in flow
position
position
position
SA1
SA1
SA5
SA9
SA2
SA6
SA10
SA2
LEDT1
LEDT1
LEDT3
LEDT5
LEDT2
LEDT2
LEDT4
LEDT6
Cassette ejection
Same as in the
routine described
in Fig.2.11.1.
If hold release error
occurs during cassette
ejection, degeneration
takes place for the
relevant shelf.
009-051-04
05.31.99 FM2460
3
4
5
6
Fig. 6.3.1 Error Handling: Recovered IP Load
Preprocessing: Fig. 2.5.3, and Fig. 2.6.6
START
Y
Value
86 p
0.5 sec
TR1H0098.EPS
4th shelf
position
SA13
SA14
LEDT7
LEDT8
TR1H0099.EPS
N
END
CR-IR341 Service Manual
7
8
9
10
Is error content out-of-spec IP?
N
Suction cup movement
Suction cup
(HP
load standby)
load preparation
DRIVE (MB1/PB14)
Reverse conveyance load
Fig.6.3.2
Elevation permission is issued
Error message
"STOP ALARM /
UNLOAD CASS."
Alarm disabled
Cassette removed
Cassette hold release
Fig.2.2.2
LEDT2 is turned on
Cassette removal
Is SA1 opened?
N
Y
DELAY TA13
Is SA2 opened?
Y
LEDT2 is turned off
LEDT1 is turned on
MD - 156
No matter whether there is any IP in the
machine or there is any unprocessed
cassette, it is placed in a queue until an
elevation permission.
Another IP in the machine proceeds
to the load standby condition.
The unprocessed cassette enters the
feed standby condition.
This elevation permission allows the
process to start.
If there is another IP in the machine,
up-down load
load.
If there is any unprocessed cassette,
up-down feed
feed.
The cassette removable
condition is indicated.