FujiFilm CR-IR341 Service Manual page 362

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
03B8/13B8
Preliminary steps:
1. Power OFF the machine and remove the covers.
2. Turn OFF the high-voltage switch (S1) of the SCN08A board.
3. Check for any foreign matter (lead character marking chips, etc.) inside the machine, and, if any, remove it all.
Power OFF
Is there any remaining IP left
in the machine?
Power ON
Is the remaining IP ejected during
initialization self-diagnostics?
Restart the machine
and check its status.
009-051-04
05.31.99 FM2460
3
4
5
6
N
Y
N
Y
CR-IR341 Service Manual
Power ON and clear "8. BACK UP MEMORY" of M-Utility.
Restart the machine again and check its status.
Manually eject the IP left in the machine.
Power ON and clear "8. BACK UP MEMORY" of M-Utility.
Restart the machine again and check its status.